# smart-oil-heating-control-system ## Software ### Design ```mermaid classDiagram Inputs <|-- Control Outputs <|-- Control Sntp <|-- Control Inputs <|-- Safety Outputs <|--|> Safety Inputs <|-- Metrics Outputs <|-- Metrics Control <|-- Metrics Safety <|-- Metrics Sntp <|-- Metrics class Inputs{ +initInputs() -taskInput() +getChamberTemperature() +getOutdoorTemperature() +getInletFlowTemperature() +getReturnFlowTemperature() +getBurnerError() } class Outputs{ +initOutputs() +getCirculationPumpState() +setCirculationPumpState() +getBurnerState() +setBurnerState() +getSafetyControlState() +setSafetyControlState() } class Control{ +taskControl() -timetable } class Safety{ +initSafety() -taskSafety() -setSafeState() -checkSensorSanity() +getSensorSanityStates() +getSafetyState() } class Wifi{ +initWifi() } class Sntp{ +initSntp() +getSntpState() } class Metrics{ +initMetrics() -taskMetrics() -metrics +event_handler() +connect_wifi() +setMetrics() } ``` ### Hardware | Function | ESP32 | PLC ES32C14 | |---------------------------------------|-------|---------------------------| | Output CirculationPump | IO27 | Relay 1 NO1 | | Output Burner Fire Signal | IO14 | Relay 2 NC2 | | Output Safety Contact (powers Burner) | IO12 | Relay 3 NC2 | | Input Burner Fault | IO19 | Digital Input IN1 | | Input Temperature DS10B20 | IO04 | 1-Wire |