increase threshold
This commit is contained in:
parent
f66b831666
commit
2477ccb42a
@ -16,7 +16,7 @@
|
||||
#define CHAMBER_TEMPERATURE_TARGET 80.0f // Max cutoff temperature
|
||||
#define CHAMBER_TEMPERATURE_THRESHOLD 45.0f // Min threshold for burner enable
|
||||
#define OUTDOOR_TEMPERATURE_THRESHOLD 15.0f // Min threshold for burner enable
|
||||
#define BURNER_FAULT_DETECTION_THRESHOLD (60U * 15U) // Burner fault detection after 15 minutes
|
||||
#define BURNER_FAULT_DETECTION_THRESHOLD (60U * 4U) // Burner fault detection after 4 minutes
|
||||
|
||||
static const char *TAG = "smart-oil-heater-control-system-control";
|
||||
static eControlState sControlState = CONTROL_STARTING;
|
||||
@ -127,7 +127,7 @@ void taskControl(void *pvParameters)
|
||||
{
|
||||
if (getBurnerError() == FAULT)
|
||||
{
|
||||
ESP_LOGW(TAG, "Burner fault detected after timeout!");
|
||||
ESP_LOGW(TAG, "Burner fault detected after threshold!");
|
||||
bHeatingInAction = false;
|
||||
eBurnerState = BURNER_FAULT;
|
||||
sControlState = CONTROL_FAULT_BURNER;
|
||||
@ -137,6 +137,7 @@ void taskControl(void *pvParameters)
|
||||
}
|
||||
else
|
||||
{
|
||||
ESP_LOGW(TAG, "No Burner fault detected after threshold!");
|
||||
eBurnerState = BURNER_FIRED;
|
||||
}
|
||||
}
|
||||
@ -157,6 +158,7 @@ void taskControl(void *pvParameters)
|
||||
(getChamberTemperature().fCurrentValue <= CHAMBER_TEMPERATURE_THRESHOLD))
|
||||
{
|
||||
ESP_LOGI(TAG, "Enabling burner: Return flow temperature target reached");
|
||||
eBurnerState = BURNER_UNKNOWN;
|
||||
bHeatingInAction = true;
|
||||
setCirculationPumpState(ENABLED);
|
||||
setBurnerState(ENABLED);
|
||||
|