suppress heating in summer

This commit is contained in:
2025-07-12 12:04:08 +02:00
parent ac15376f6b
commit 6eca00200e

View File

@ -15,7 +15,8 @@
#define RETURN_FLOW_TEMPERATURE_LOWER_LIMIT_NIGHT 25.0f
#define CHAMBER_TEMPERATURE_TARGET 80.0f // Max cutoff temperature
#define CHAMBER_TEMPERATURE_THRESHOLD 45.0f // Min threshold for burner enable
#define OUTDOOR_TEMPERATURE_THRESHOLD 15.0f // Min threshold for burner enable
#define OUTDOOR_TEMPERATURE_THRESHOLD 13.0f // Min threshold for burner enable
#define CIRCULATION_PUMP_TEMPERATURE_THRESHOLD 30.0f // Min threshold of chamber for circulation pump enable
#define BURNER_FAULT_DETECTION_THRESHOLD (60U * 4U) // Burner fault detection after 4 minutes
static const char *TAG = "smart-oil-heater-control-system-control";
@ -162,8 +163,7 @@ void taskControl(void *pvParameters)
}
// Manage circulation pump
if ((getReturnFlowTemperature().average60s.fValue <= currentControlEntry.fReturnFlowTemperature) &&
(getChamberTemperature().fCurrentValue <= CHAMBER_TEMPERATURE_THRESHOLD))
if (getChamberTemperature().fCurrentValue <= CIRCULATION_PUMP_TEMPERATURE_THRESHOLD)
{
// ESP_LOGI(TAG, "Burner cooled down: Disabling circulation pump");
setCirculationPumpState(DISABLED);