* @file control.h
* @brief Heating control logic with schedule-based temperature management.
*
* This module implements the main heating control loop. It manages
* burner operation based on time schedules, temperature targets,
* and summer mode detection.
*/
#pragma once
#include "sdkconfig.h"
#include "esp_err.h"
#include <stdint.h>
#include <stddef.h>
/** @brief Maximum number of temperature entries per day. */
#define MAX_TEMPERATURE_ENTRIES_PER_DAY 24U
/** @brief Return flow target temperature for day mode (°C). */
#define RETURN_FLOW_TEMPERATURE_LOWER_LIMIT_DAY (CONFIG_TEMP_RETURN_FLOW_LOWER_LIMIT_DAY / 10.0f)
/** @brief Return flow target temperature for night mode (°C). */
#define RETURN_FLOW_TEMPERATURE_LOWER_LIMIT_NIGHT (CONFIG_TEMP_RETURN_FLOW_LOWER_LIMIT_NIGHT / 10.0f)
/** @brief Chamber target temperature (°C). */
#define CHAMBER_TEMPERATURE_TARGET (CONFIG_TEMP_CHAMBER_TARGET / 10.0f)
/** @brief Chamber temperature threshold to enable burner (°C). */
#define CHAMBER_TEMPERATURE_THRESHOLD (CONFIG_TEMP_CHAMBER_THRESHOLD / 10.0f)
/** @brief Outdoor temperature to activate summer mode (°C). */
#define SUMMER_MODE_TEMPERATURE_THRESHOLD_HIGH (CONFIG_TEMP_SUMMER_MODE_HIGH / 10.0f)
/** @brief Outdoor temperature to deactivate summer mode (°C). */
#define SUMMER_MODE_TEMPERATURE_THRESHOLD_LOW (CONFIG_TEMP_SUMMER_MODE_LOW / 10.0f)
/** @brief Chamber temperature threshold for circulation pump (°C). */
#define CIRCULATION_PUMP_TEMPERATURE_THRESHOLD (CONFIG_TEMP_CIRCULATION_PUMP_THRESHOLD / 10.0f)
/** @brief Time to wait before checking burner fault (seconds). */
#define BURNER_FAULT_DETECTION_THRESHOLD CONFIG_BURNER_FAULT_DETECTION_SECONDS
/**
* @brief Control state enumeration.
*/
typedef enum _ControlState
{
CONTROL_STARTING, /**< System starting up. */
CONTROL_HEATING, /**< Burner running. */
CONTROL_OUTDOOR_TOO_WARM, /**< Summer mode active. */
CONTROL_RETURN_FLOW_TOO_WARM, /**< Target temperature reached. */
CONTROL_FAULT_BURNER, /**< Burner fault detected. */
CONTROL_FAULT_SAFETY, /**< Safety fault detected. */
CONTROL_FAULT_SNTP, /**< SNTP sync failed. */
} eControlState;
/**
* @brief Burner operational state enumeration.
*/
typedef enum _BurnerState
{
BURNER_UNKNOWN, /**< Burner state unknown after enable. */
BURNER_FIRED, /**< Burner fired successfully. */
BURNER_FAULT /**< Burner failed to fire. */
} eBurnerState;
/**
* @brief Weekday enumeration (Monday = 0).
*/
typedef enum _ControlWeekday
{
MONDAY,
TUESDAY,
WEDNESDAY,
THURSDAY,
FRIDAY,
SATURDAY,
SUNDAY,
} eControlWeekday;
/**
* @brief Time of day structure.
*/
typedef struct _ControlTimestamp
{
uint8_t hour; /**< Hour (0-23). */
uint8_t minute; /**< Minute (0-59). */
} sControlTimestamp;
/**
* @brief Temperature schedule entry.
*/
typedef struct _ControlTemperatureEntry
{
sControlTimestamp timestamp; /**< Time when entry becomes active. */
float fReturnFlowTemperature; /**< Target return flow temperature. */
float fChamberTemperature; /**< Target chamber temperature. */
} sControlTemperatureEntry;
/**
* @brief Daily schedule structure.
*/
typedef struct _ControlDay
{
eControlWeekday day; /**< Day of week. */
size_t entryCount; /**< Number of entries for this day. */
sControlTemperatureEntry aTemperatureEntries[MAX_TEMPERATURE_ENTRIES_PER_DAY]; /**< Schedule entries. */
} sControlDay;
/**
* @brief Initialize the control module.
*
* Creates the control task that manages heating operation.
*
* @return ESP_OK on success, ESP_FAIL on error.
*/
esp_err_t initControl(void);
/**
* @brief Get the current control state.
* @return eControlState indicating current operation mode.
*/
eControlState getControlState(void);
/**
* @brief Get the current weekday.
* @return eControlWeekday (Monday = 0, Sunday = 6).
*/
eControlWeekday getControlCurrentWeekday(void);
/**
* @brief Get the currently active temperature entry.
* @return sControlTemperatureEntry with current targets.
*/
sControlTemperatureEntry getControlCurrentTemperatureEntry(void);