Fix: Mutex in getter of safety state #9

Merged
localhorst merged 1 commits from bugfix/get-safety-state-critial-section into main 2024-12-25 22:56:04 +01:00
Owner

Protec the safety state var via mutex

Protec the safety state var via mutex
localhorst added the
bug
label 2024-12-25 22:55:41 +01:00
localhorst added 1 commit 2024-12-25 22:55:41 +01:00
localhorst merged commit 8effd730b9 into main 2024-12-25 22:56:04 +01:00
localhorst deleted branch bugfix/get-safety-state-critial-section 2024-12-25 22:56:04 +01:00
Sign in to join this conversation.
No reviewers
No Milestone
No project
No Assignees
1 Participants
Notifications
Due Date
The due date is invalid or out of range. Please use the format 'yyyy-mm-dd'.

No due date set.

Dependencies

No dependencies set.

Reference: localhorst/smart-oil-heating-control-system#9
No description provided.