smart-oil-heating-control-s.../README.md
2024-12-11 22:03:49 +01:00

68 lines
1.4 KiB
Markdown

# smart-oil-heating-control-system
## Software
### Design
```mermaid
classDiagram
Inputs <|-- Control
Outputs <|-- Control
Inputs <|-- Safety
Outputs <|--|> Safety
Inputs <|-- HTTP_Metrics
Outputs <|-- HTTP_Metrics
Control <|-- HTTP_Metrics
Safety <|-- HTTP_Metrics
class Inputs{
+initInputs()
-taskInput()
+getChamberTemperature()
+getOutdoorTemperature()
+getInletFlowTemperature()
+getReturnFlowTemperature()
+getBurnerError()
}
class Outputs{
+initOutputs()
+getCirculationPumpState()
+setCirculationPumpState()
+getBurnerState()
+setBurnerState()
}
class Control{
+taskControl()
-timetable
}
class Safety{
+initSafety()
-taskSafety()
-setSafeState()
-checkSensorSanity()
+getSafetyState()
}
class Metrics{
+initMetrics()
-taskMetrics()
-metrics
+event_handler()
+connect_wifi()
+setMetrics()
}
```
### Hardware
| Function| ESP32 | ES32C14 |
|-----------------------|-------|---------------------------|
| CirculationPump | IO27 | Relay 1 NO1 |
| Burner | IO14 | Relay 1 NC2 |
| Burner Fault | IO19 | Digital Input IN1 |
| Temperature DS10B20 | IO04 | 1-Wire |